Laboratory

Air Conditioner

İmbat laboratory room air conditioners are designed for spaces such as test rooms and laboratories that require different and more precise climate control conditions than those for human comfort.

İmbat’s panel room air conditioners have been developed to maintain temperature and humidity values within narrow tolerances to eliminate issues such as equipment overheating, data loss, oxidation, short service life, premature damage, and physical damage to backup units in laboratories and test rooms.

Product Features

  • 6-150 kW capacity range

  • R-410a, R-32 refrigerants

  • 7/12°C chilled water

  • Heating

  • Cooling

  • Humidity control

  • Scroll compressor

  • EC fan

  • Fully automatic

  • Asymmetric cooling circuit

  • Fresh air

  • Temperature, humidity, and indoor air quality control

  • Variable air volume and low energy consumption with EC or plug fan models

  • Electronic expansion valve

  • Advanced electronic control panel for daily and weekly programming, and fully automatic operation

  • Remote control and monitoring with the ability to connect to a building management system

  • Two-stage filtration (G4+F7)

  • Water-cooled models

  • Temperature and humidity accuracy (+/- 1°C T, +/- 2% RH)

  • Chilled water models

  • Models suitable for low ambient temperatures (down to -45°C)

  • Flexibility in design and production for special projects

High Sensible Heat Ratio

Spaces such as server rooms, museums, laboratories, panel rooms, electrical and electronic equipment rooms, and computer and telecommunication systems have different design criteria than those for human comfort. İmbat precision air conditioners were developed to maintain the necessary humidity and temperature values within narrow tolerances to eliminate issues like overheating, data loss, oxidation, short service life, premature damage, and physical damage to backup units in equipment, test rooms, and telecommunication systems.

Automatic Humidification and Dehumidification

High humidity can cause condensation on electronic equipment, while low humidity leads to static electricity buildup. Uncontrolled humidity can result in oxidation on magnetic surfaces, which can damage equipment and cause data loss or corruption. With İmbat precision air conditioners, the ambient temperature is always maintained at the desired value with a tolerance of up to +/-1°C, and the ambient relative humidity is maintained at the desired level with a tolerance of up to +/-2%.